ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â

°æµµ½ÃÇè±â

¢¹ °æµµ½ÃÇè±â > ºñÄ¿½º°æµµ°è > ºñÄ¿½º°æµµ°è(HWDV-7/ HWDV-7S)

 

 

ºñÄ¿½º°æµµ°è(HWDV-7/ HWDV-7S)

¸ðµ¨¸í

:

HWDV-7/ HWDV-7S

ÆǸŰ¡

:

ÀüÈ­¹®ÀÇ¿ø

¼ÒºñÀÚ°¡°Ý

:

0¿ø

Àû¸³±Ý

:

0¿ø

Á¦Á¶»ç

:

HIGHWOOD

¿ø»êÁö

:

ÀϺ»

¼ö·®

:

EA

ȯÀ²À̳ª °ø±Þ»çÀÇ »çÁ¤¿¡ ÀÇÇØ º¯µ¿ µÉ ¼ö ÀÖÀ¸´Ï ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.

¸ðµç »óÇ°Àº ºÎ°¡¼¼ º°µµÀÔ´Ï´Ù.

»óÇ° »ó¼¼ ¼³¸í
 

¡á Æ¯Â¡ (Features)

   -  ÀÚµ¿ Turret  ;  ÀÚµ¿ Turret ½ÇÇöÀ¸·Î Á¤¹Ð ÃøÁ¤ÀÌ °¡´ÉÇÔ.

   -  Á¢Ã˽Ġ¾×Á¤ È­¸é ;  ¹à°í Å« ¾×Á¤ È­¸éÀ¸·Î È­¸éÀ§¿¡¼­ Á¢ÃËÇÏ¿© ½ÃÇè ¼öÇà °¡´É.

   -  Á¤È®ÇÑ ÇÏÁß ½ÇÇö ;  Á¤¹ÐÇÑ Turret ·Î ÃøÁ¤ÇÏ°íÀÚ Çϴ Áö¿ªÀ» Á¤È®ÇÏ°Ô ÃøÁ¤°¡´É.

   -  HK Knoop °æµµ°ª :  Knoop °æµµ´Â È­¸éÀ§¿¡¼­ ÇѹøÀÇ Á¢ÃËÀ¸·Î ÀÚµ¿ °è»ê ¼öÇà

   -  »õ·Ó°Ô µðÀÚÀεȠº»Ã¼·Î ÀÎÇØ °íÁ¤¹Ð¼º ÃøÁ¤ °¡´É.

   -  µÎ °³ÀÇ ´ë¾È·£Áî ¼³Ä¡ °¡´É :  X10, X20 ÀÇ ´ë¾È ·£Á µ¿½Ã¿¡ ¼³Ä¡ °¡´É

   -  ¾ÈÀüÇÑ ±¸Á¶ : °úºÎÇÏ ¹× ÁöÁøµî¿¡µµ ÃÊ°ú ÇÏÁßÀÌ °É¸®Áö ¾ÊÀº ¼³°è

 ¡á Specifications(»ç¾ç)

 

ITEM

CONTENS

Test load

HWDV-7

 9.807     49.03     98.07    196.1     294.2     190.3     N

       1           5         10        20          30         50     Kgf

HWDV-7S

 2.942     4.903     9.807     49.03    98.07     196.1     N

    0.3        0.5           1          5          10        20      Kgf

 Loading mechanism

 Automatic loading releasing method

Auto-turret

 Objec lens = Diamond indenter = Object lens Auto.

Load applying speed

 85 um / sec

Dwell time

 5 - 99 sec (Key entry in units of seconds)

Magnification of microscope

HWDV-7

 x 100 (Object lens x 10, eyepiece x 10)

HWDV-7S

 x 200 (Object lens x 20, eyepiece x 10)

Data output

 1) Centronics (standard)

 2) RS232C or serial output selectable (Factory setting :RS232C)

Data memory

 Max. 256 test data

 Hardness converstion

 Possible in compliance with ASTM (E-140), JIS

 OK / NG criteria

 Upper and lower limits setting, and HI/OK/LOW display

 Data edition

 Data output and display : Max.value, Min.value,dispersion(R),STD

 deviation

RS-232C Communication line

 Baud rete : 1200/2400/4800/9600 bps selectable(RS232C)

 Error detection, Parity even / Parity none / selectable (RS232C)

 Accuracy

 Conform to JIS B7725 and ASTM-384

 Max. measuring length

HWDV-7

 999.9 um

HWDV-7S

 600.0 um

 Min. measuring unit

 0.1 um

Max. specimen height

 260 mm

Max. specimen depth

 160 mm

 Dimensions & Weight

W220 x D580 xH770 , 70 Kg

 Power supply

 Single phase AC 100 - 240V 50/60 Hz available for export model

 subject to chan without prior notic specification

 

¡á Standard Accessories

ITEM

HWDV-7

HWDV-7S

Hardness standard block

HV 800

1

1

Diamond indenter (Built in)

1

1

Electronic measuring microscope

1

1

Object lens (Built in)

X 10

1

-

X 20

-

1

Anvil

60mm x flat

1

1

V-shape

1

1

Small level

1

1

Spare light source bulb(12V, 18W)

2

2

Spare fuse 200 - 240 V 2A

2

2

Power cord(3P-2.5m)

1

1

Level adjusting leg

4

4

Auxiliary tools

1

1

Attachment for prevent the machine fall

1

1

Machine cover

1

1

 

¡á Optional Accessories

Item

Contents

Knoop indenter

Effectively measuring thin material.

Camera attachment

Adapter for a camera

Photographic device

Polaroide camera : PM-10M-pola

35mm camera : PM-10M with FK x 3.3 relay lens

Precision vice

Max. opening : 50 mm and 100 mm

Rotary table

This table is usually used on the micro test table

Thin specimen

measuring device

Specimen thickness : 0 - 5 mm

Fine specimen

measuring device

 

Vertical type

Horizontal type

For measuring the cross setion (the cylindrical

surface) on the specimens.

 

Specimen diameter : 0.1 - 4 mm

Specimen diameter : 0.5 - 4 mm

Specimen inclining

device type II

The measuring surface always shows a horizontal

level and causes an extremely efficient measuring

operation.

V-shape anvil(small)

For measuring the cylindrical surface together with

 the vice

Manual X-Y stage

Max. movement : X and Y axis 25 mm and 50 mm

Round table

200 m dia. (Not tempered)

 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
 

647-21-01142 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ]