ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â

¾Ð·Â/Áø°ø°è

¢¹ ¾Ð·Â/Áø°ø°è > ¾Ð·Â°ÔÀÌÁö > ¾Ð·Â°è Pressure Reference Type L

 

 

¾Ð·Â°è Pressure Reference Type L

¸ðµ¨¸í

:

Pressure Reference Type L

ÆÇ¸Å°¡

:

ÀüÈ­¹®ÀÇ¿ø

¼ÒºñÀÚ°¡°Ý

:

0¿ø

Àû¸³±Ý

:

0¿ø

Á¦Á¶»ç

:

SIKA

¿ø»êÁö

:

µ¶ÀÏ

¼ö·®

:

EA

ȯÀ²À̳ª °ø±Þ»çÀÇ »çÁ¤¿¡ ÀÇÇØ º¯µ¿ µÉ ¼ö ÀÖÀ¸´Ï ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.

¸ðµç »óǰÀº ºÎ°¡¼¼ º°µµÀÔ´Ï´Ù.

»óǰ »ó¼¼ ¼³¸í
 
  • Pressure media: Air, Water, Oil etc
  • ÃøÁ¤¹üÀ§: -1~20 or 0~200, 400, 1000 bar
  • Accuracy: +/-0.01% v.E +/-1 digit for Model B
  • +/-0.025% v.E +/-1 digit for Model A

    media air, gas, liquid
    measuring range -1...20, 0...200, 0...400 or 0...1000 bar
    display multifunction LCD display, 30 x 30 mm
    function keys SELECT (on/off, function, units)
    ENTER (confirm, min/max)
    switchable pressure units bar, mbar, hPa, PSI, kPa, MPa, PS I, kp/cm2, cmH20, mH20, inH20, ftH20, mmHg, inHg
    compensation of temperature influence (0...50 ¡É)
    pressure connection G 1/4
    serial interface RS485 or USB
    protection class IP 65
    Power supply 3V battery, 2000 working hours LOW BAT display, AUTO OFF
    measuring range / resolution
               -1...20 bar /1 mbar
              0...200 bar / 10 mbar
              0...400 bar / 50 mbar
            0...1000 bar /100 mbar
    accuracy +/-0.025 % v.E. +/-1 digit (Model A)
    +/- 0,01 % v.E. +/-1 digit (Model B)
    dimension approx. 76 x 118 x 42 mm (¨ª x H x T)
    weight app. 210 g
  •  
     
     
    À̸§ :
    ³»¿ë :
    ÆòÁ¡
    °í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
     
     
     
     
     