ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â

¾Ð·Â/Áø°ø°è

¢¹ ¾Ð·Â/Áø°ø°è > ¾Ð·ÂÁø°øÆ®·£½º¸ÞÅÍ > ¾Ð·Â¼¾½º Á¤¹ÐÇü P3276

 

 

¾Ð·Â¼¾½º Á¤¹ÐÇü P3276

¸ðµ¨¸í

:

P3276

ÆÇ¸Å°¡

:

ÀüÈ­¹®ÀÇ¿ø

¼ÒºñÀÚ°¡°Ý

:

0¿ø

Àû¸³±Ý

:

0¿ø

Á¦Á¶»ç

:

tecsis GmbH

¿ø»êÁö

:

µ¶ÀÏ

¼ö·®

:

EA

ȯÀ²À̳ª °ø±Þ»çÀÇ »çÁ¤¿¡ ÀÇÇØ º¯µ¿ µÉ ¼ö ÀÖÀ¸´Ï ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.

¸ðµç »óǰÀº ºÎ°¡¼¼ º°µµÀÔ´Ï´Ù.

»óǰ »ó¼¼ ¼³¸í
 
  • Á¤¹ÐÇü pressure transmitter
  • 4~20mA or 0~10VDC Ãâ·Â [others on request]
  • Áøµ¿ ¹× ¼îÅ©¿¡ ¿ì¼öÇÔ
  • 0.25~0.5% Á¤¹Ð±Þ

    Model
    P3276
    Option
    tecsis
    P3276
    Pressure type negative or positive gauge pressure absolute pressure negative or positive gauge
    pressure
    Output signal 4...20 mA - 2-wire
    0... 5 VDC - 3-wire
    0...10 VDC - 3-wire
    other signals
    on request
    Accuracy % of F. S. 1) 0,5
    0,25% BFSL
    0,25
    0,13% BFSL
    0,5
    0,25% BFSL
    0,25
    0,13% BFSL
    0,5
    0,25% BFSL
    0,25
    0,13% BFSL
     
    Ranges accord. to EN 0...0.1 bar 2)
    to
    0...25 bar
    0...40 bar
    to
    0...2500 bar
    0...25 bar
    to
    0...16 bar
    0...25 mbar 3)
    0...40 mbar
    0...60 mbar
    Sensor element piezoresistive Thin film piezoresistive  
    Non-linearity ¡Â ¡¾ 0.2% of F. S.
    Non-repeatability ¡Â ¡¾ 0.1% of F. S.
    Stability (annual) ¡Â ¡¾ 0.2% of F. S. in reference conditions
    Case Stainless steel
    Pressure connection 4) G 1/2 B to EN837 G 1/4 B; 1/4 NPT; 1/2 NPT
    Wetted parts Stainless steel  
    Overload limit ¡Â 16 bar 3,5 x; ¡Â 600 bar 2 x; > 600 bar 1.5 x;
    ¡Ã 1600 bar 1,2 x
    Electrical connection plug according to DIN EN 175301-803 form A with junction box
    round connector M12x1; 4-pin
    cable outlet
    with 1 m cable
    Power supply 10...30 VDC (14...30 VDC for output 0...10 V)  
    Power consumption current output 4...20mA: signal currency
    voltage output: 8 mA
     
    for output (0)4...20mA
    Load
    ¡ÂUB-10V/0,02A for output 4...20mA two wire
    > 5kOhm for output 0 . . . 5 V
    >10kOhm for output 0 . . .10V
     
    Temp.compens. range 0 . . . 80 ¡É  
    Temperature influence
    - Zero point
    - Measuring range

    ¡¾0.2% / 10 K 5)
    ¡¾0.2% / 10 K
     
    Adjustability zero point and full scale up to ¡¾ 5%  
    Response time ¡Â 1 ms (within 10% to 90% of F.S)  
    Protection type IP 65 to EN 60 529 / IEC 529
    IP 67 to M12x1 connector
    IP 67 for cable outlet

    CE-conformity 6)
    -pressure equipment
    Directive
    EMC directive

    97/23/EC

    2004/108/EEC, EN 61326 Emission (Group 1, Class B) and immunity
    (industrial location)

     
    Electrical protection types polarity, overload and short-circuit protection  
    Insulation voltage 500VDC  
    Temperature ranges
    - Storage
    - Medium
    - Ambient

    -40 . . . 100 ¡É
    -30 . . . 100 ¡É
    -20 . . . 80 ¡É

    media temperature
    -40 . . . 125 ¡É
    Weight approx. 0.2 kg  
  •  
     
     
    À̸§ :
    ³»¿ë :
    ÆòÁ¡
    °í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
     
     
     
     
     

    647-21-01142 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ]